Smart Locks, Screening & Mail
API keyEcobee Smart Thermostats & Tenant Office
Vacant units left heating or cooling at extreme temperatures—or cold snaps threatening burst pipes during winter turns—create avoidable maintenance damage. Connect Ecobee smart thermostats through Seam’s unified climate API key so property teams can coordinate vacant-unit setback presets, monitor indoor temperature alerts, and hand climate control cleanly back at lease move-in.
- Estimated setup time
- 15–20 minutes
- Required role
- Organization administrator & maintenance supervisor
- Connection method
- API key
Setup path: Connects through Seam’s unified thermostat API using your Seam workspace API key—zero separate Ecobee developer approval required.
What connects
What flows between Ecobee Smart Thermostats and Tenant Office.
- Ecobee thermostat device IDs mapped to Tenant Office properties and units
- Vacant-unit climate setback presets aligned with move-out and unit-turn status
- High/low indoor temperature threshold alerts routed into maintenance notifications
- Thermostat connectivity and HVAC mode telemetry surfaced via Seam’s API
Before you start
Prerequisites for setting up Ecobee Smart Thermostats.
Confirm these items before starting so your setup completes cleanly in 15–20 minutes.
- Ecobee smart thermostats installed and connected to property Wi-Fi inside your Ecobee account.
- A Seam workspace connected to your Ecobee account with a Seam API key.
- A unit-to-device lookup table matching each Tenant Office `unit.id` to its Seam `device_id`.
- Written vacant-unit temperature bounds (for example, 55°F min heat in winter, 80°F max cool in summer) aligned with local climate.
Step-by-step tutorial
4 steps to set up Ecobee Smart Thermostats.
Follow these steps as an organization administrator & maintenance supervisor to configure and test your Ecobee Smart Thermostats workflow.
Link your Ecobee account inside Seam
Authorize your Ecobee account in your Seam workspace so installed Ecobee thermostats are accessible through Seam’s unified climate API.
Map each thermostat to a Tenant Office unit
Use your Seam API key to associate each Ecobee device ID with its corresponding Tenant Office unit record.
Apply setback presets on vacant turns
Trigger vacant-unit heating/cooling bounds during move-out turns and return thermostats to normal resident control upon lease start.
Route extreme-temperature warnings into work orders
Alert maintenance staff via Slack, Teams, or email when a vacant unit drops near freezing or an HVAC unit stops responding.
End-to-end example workflow
How property teams run Ecobee Smart Thermostats day to day
During a January freeze, a maintenance supervisor monitors twelve vacant apartment turns whose Ecobee thermostats are linked through Seam. Each unit automatically holds a 58°F winter setback after move-out; when Unit 108 drops to 49°F overnight because a furnace igniter failed, Seam’s telemetry alerts the team’s Slack channel, and the supervisor opens an urgent work order in Tenant Office before pipes can freeze.
Field mapping & reference
Exact fields, endpoints, and data mapping.
Reference how Tenant Office records, headers, or API endpoints align with Ecobee Smart Thermostats before running your first live workflow.
| Tenant Office field / endpoint | Ecobee Smart Thermostats field / target | Mapping notes |
|---|---|---|
| Tenant Office unit.id | Seam device_id (ecobee_thermostat) | Associates each Ecobee thermostat with the exact rental unit in Tenant Office. |
| unit.status = vacant / turn | Seam /thermostats/heat_cool (heating_set_point_fahrenheit, cooling_set_point_fahrenheit) | Applies safe vacant-unit climate setback bounds while a unit sits empty between leases. |
| Lease start date (move-in) | Seam /thermostats/set_climate_setting_schedule | Returns the thermostat to normal resident comfort settings when a household moves in. |
| Urgent HVAC maintenance alert | Ecobee temperature_fahrenheit & offline telemetry via Seam | Triggers Slack/Teams alerts if a vacant unit drops toward freezing or exceeds safe humidity/heat limits. |
Verification & troubleshooting
How to verify Ecobee Smart Thermostats is working.
Run through these checks after completing setup to confirm clean delivery, scoping, and audit trails.
- Verify every Ecobee thermostat appears online in Seam with current indoor temperature readings.
- Apply a vacant setback preset on one empty unit and confirm the thermostat display reflects the updated heat/cool bounds.
- Verify your workflow does NOT push vacant setback overrides to occupied units.
- Test a low-temperature threshold alert to confirm maintenance staff receive immediate notification.
Common issues & fixes
Quick symptom, cause, and resolution guidance for the edge cases property teams encounter most often with Ecobee Smart Thermostats.
Setback temperatures revert automatically a few hours after being set.
- Likely cause
- The Ecobee’s internal comfort schedule or "Hold Duration" setting (for example, "Until the next scheduled activity") overrode the temporary hold.
- How to fix
- Configure vacant presets via Seam’s climate setting presets or set Ecobee hold behavior appropriately for vacant units.
Ecobee thermostat stops reporting temperature during a turn.
- Likely cause
- Power was shut off at the breaker during turn electrical work or the outgoing resident cancelled unit Wi-Fi.
- How to fix
- Verify HVAC breaker power and confirm vacant-unit network access so freeze alerts keep working during winter turns.
Heating and cooling setpoints fail validation with a deadband error.
- Likely cause
- Ecobee requires a minimum temperature deadband (typically 5°F) between the heating and cooling setpoints in auto heat/cool mode.
- How to fix
- Keep at least a 5°F–10°F gap between `heating_set_point_fahrenheit` and `cooling_set_point_fahrenheit` (for example, 58°F heat / 78°F cool).
Questions (5)
Ecobee Smart Thermostats FAQ
Detailed answers covering workflow scope, role permissions, pricing, edge cases, and data ownership.
Do I need a separate Ecobee partner agreement to connect thermostats?
No. Ecobee connects through the same Seam workspace API key you use for Yale, Schlage, August, and Kwikset locks.
How do property teams use Ecobee during winter unit turns?
Teams apply safe vacant-unit temperature setbacks after move-out and route low-temperature alerts into their maintenance workflow to catch HVAC failures before pipes freeze.
Will Tenant Office override an occupied resident’s Ecobee thermostat?
No. Climate setback presets should target vacant or mid-turn units only; Tenant Office never overrides occupied resident climate controls without operator policy and lease authority.
Does Tenant Office charge an extra fee per Ecobee thermostat?
No. Customer API and webhook capabilities are included in Tenant Office’s operations package without per-device markups; Seam bills connected devices separately.
Why did Ecobee reject our vacant heat/cool setpoint range?
Ecobee requires a minimum deadband (typically 5°F) between heating and cooling setpoints in auto mode—for example, 58°F heat and 78°F cool.